Probe #1da0f736d4 of Acer Nitro AN515-47

Log: smartctl

/dev/nvme0n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.9-200.fsync.fc41.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: TEAM TM8FP6002T Serial Number: -- Firmware Version: SN10660 PCI Vendor/Subsystem ID: 0x1e4b IEEE OUI Identifier: 0x3a5a27 Total NVM Capacity: 2,048,408,248,320 [2.04 TB] Unallocated NVM Capacity: 0 Controller ID: 0 NVMe Version: 1.4 Number of Namespaces: 1 Namespace 1 Size/Capacity: 2,048,408,248,320 [2.04 TB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 3a5a27 ... Local Time is: Sun Jan 12 18:41:28 2025 EST Firmware Updates (0x1a): 5 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 90 Celsius Critical Comp. Temp. Threshold: 95 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.50W - - 0 0 0 0 0 0 1 + 5.80W - - 1 1 1 1 0 0 2 + 3.60W - - 2 2 2 2 0 0 3 - 0.0500W - - 3 3 3 3 5000 10000 4 - 0.0480W - - 4 4 4 4 8000 45000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 35 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 1% Data Units Read: 15,380,510 [7.87 TB] Data Units Written: 25,438,632 [13.0 TB] Host Read Commands: 107,811,166 Host Write Commands: 99,430,704 Controller Busy Time: 636 Power Cycles: 34,264 Power On Hours: 3,379 Unsafe Shutdowns: 30 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 35 Celsius Temperature Sensor 2: 37 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged Read Self-test Log failed: Invalid Field in Command (0x002) /dev/nvme1n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.9-200.fsync.fc41.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: SAMSUNG MZVL2512HCJQ-00B07 Serial Number: -- Firmware Version: GXA7402Q PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 512,110,190,592 [512 GB] Unallocated NVM Capacity: 0 Controller ID: 6 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 512,110,190,592 [512 GB] Namespace 1 Utilization: 123,153,256,448 [123 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Sun Jan 12 18:41:28 2025 EST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x0057): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 81 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 8.37W - - 0 0 0 0 0 0 1 + 8.37W - - 1 1 1 1 0 200 2 + 8.37W - - 2 2 2 2 0 200 3 - 0.0500W - - 3 3 3 3 2000 1200 4 - 0.0050W - - 4 4 4 4 500 9500 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 35 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 1% Data Units Read: 11,428,753 [5.85 TB] Data Units Written: 14,117,394 [7.22 TB] Host Read Commands: 94,254,034 Host Write Commands: 197,454,645 Controller Busy Time: 699 Power Cycles: 35,484 Power On Hours: 401 Unsafe Shutdowns: 34 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 35 Celsius Temperature Sensor 2: 37 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged Read Self-test Log failed: Invalid Field in Command (0x002)


Hardware for Linux and BSD

GitHub