/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-5.19.10-300.fc37.x86_64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1ER166
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: CC25
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Sep 25 00:14:10 2022 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 80) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 318) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x1085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 118 089 006 - 180148720
3 Spin_Up_Time PO---- 095 094 000 - 0
4 Start_Stop_Count -O--CK 094 094 020 - 6599
5 Reallocated_Sector_Ct PO--CK 099 099 010 - 968
7 Seek_Error_Rate POSR-- 084 060 030 - 9192965194
9 Power_On_Hours -O--CK 071 071 000 - 25565
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 094 094 020 - 6548
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 001 001 000 - 697
188 Command_Timeout -O--CK 100 098 000 - 2 10 40
189 High_Fly_Writes -O-RCK 076 076 000 - 24
190 Airflow_Temperature_Cel -O---K 064 049 045 - 36 (Min/Max 21/38)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1747
193 Load_Cycle_Count -O--CK 095 095 000 - 10144
194 Temperature_Celsius -O---K 036 051 000 - 36 (0 10 0 0 0)
197 Current_Pending_Sector -O--C- 100 095 000 - 0
198 Offline_Uncorrectable ----C- 100 095 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
240 Head_Flying_Hours ------ 100 253 000 - 25621h+00m+55.147s
241 Total_LBAs_Written ------ 100 253 000 - 84506707322
242 Total_LBAs_Read ------ 100 253 000 - 5673354793554
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 4496 Device vendor specific log
0xa8 GPL,SL VS 129 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 5176 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL,SL VS 10 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 791 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 791 [10] occurred at disk power-on lifetime: 23878 hours (994 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 71 00 00 00 00 00 00 00 81 e0 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b4 00 00 00 00 00 00 00 00 00 00 a0 00 03:16:51.602 SANITIZE DEVICE
b4 00 00 00 00 00 00 00 00 00 00 a0 00 03:16:36.583 SANITIZE DEVICE
b4 00 00 00 00 00 00 00 00 00 00 a0 00 03:16:21.563 SANITIZE DEVICE
b4 00 00 00 00 00 00 00 00 00 00 a0 00 03:16:06.544 SANITIZE DEVICE
b4 00 00 00 00 00 00 00 00 00 00 a0 00 03:15:51.524 SANITIZE DEVICE
Error 790 [9] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 94 38 00 00
Error: UNC at LBA = 0xf4299438 = 4096365624
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 08 00 00 f4 29 94 38 e0 00 00:41:46.533 READ VERIFY SECTOR(S) EXT
ea 00 00 00 00 00 00 00 00 00 00 a0 00 00:41:46.523 FLUSH CACHE EXT
35 00 00 00 08 00 00 f4 29 94 38 e0 00 00:41:46.523 WRITE DMA EXT
47 00 00 00 01 00 00 00 00 00 07 e0 00 00:41:46.453 READ LOG DMA EXT
b0 00 d0 00 01 00 00 00 c2 4f 00 e0 00 00:41:46.310 SMART READ DATA
Error 789 [8] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 94 38 00 00
Error: UNC at LBA = 0xf4299438 = 4096365624
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 08 00 00 f4 29 94 38 e0 00 00:41:46.533 READ VERIFY SECTOR(S) EXT
ea 00 00 00 00 00 00 00 00 00 00 a0 00 00:41:46.523 FLUSH CACHE EXT
35 00 00 00 08 00 00 f4 29 94 38 e0 00 00:41:46.523 WRITE DMA EXT
47 00 00 00 01 00 00 00 00 00 07 e0 00 00:41:46.453 READ LOG DMA EXT
b0 00 d0 00 01 00 00 00 c2 4f 00 e0 00 00:41:46.310 SMART READ DATA
Error 788 [7] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 79 e0 00 00
Error: UNC at LBA = 0xf42979e0 = 4096358880
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 08 00 00 f4 29 76 48 e0 00 00:40:55.048 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 40 e0 00 00:40:55.031 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 38 e0 00 00:40:55.007 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 30 e0 00 00:40:54.999 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 28 e0 00 00:40:54.990 READ VERIFY SECTOR(S) EXT
Error 787 [6] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 79 e0 00 00
Error: UNC at LBA = 0xf42979e0 = 4096358880
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 08 00 00 f4 29 76 48 e0 00 00:40:55.048 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 40 e0 00 00:40:55.031 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 38 e0 00 00:40:55.007 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 30 e0 00 00:40:54.999 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 76 28 e0 00 00:40:54.990 READ VERIFY SECTOR(S) EXT
Error 786 [5] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 6c 70 00 00
Error: UNC at LBA = 0xf4296c70 = 4096355440
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 08 00 00 f4 29 6c 70 e0 00 00:40:50.706 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 68 e0 00 00:40:50.698 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 60 e0 00 00:40:50.690 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 58 e0 00 00:40:50.681 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 48 e0 00 00:40:50.597 READ VERIFY SECTOR(S) EXT
Error 785 [4] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 6c 70 00 00
Error: UNC at LBA = 0xf4296c70 = 4096355440
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 08 00 00 f4 29 6c 70 e0 00 00:40:50.706 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 68 e0 00 00:40:50.698 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 60 e0 00 00:40:50.690 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 58 e0 00 00:40:50.681 READ VERIFY SECTOR(S) EXT
42 00 00 00 08 00 00 f4 29 6c 48 e0 00 00:40:50.597 READ VERIFY SECTOR(S) EXT
Error 784 [3] occurred at disk power-on lifetime: 23872 hours (994 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 53 00 00 00 00 f4 29 6c 70 00 00
Error: UNC at LBA = 0xf4296c70 = 4096355440
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 27 17 00 00 f4 29 62 b0 e0 00 00:40:46.464 READ VERIFY SECTOR(S) EXT
42 00 00 13 88 00 00 00 00 00 00 e0 00 00:40:46.435 READ VERIFY SECTOR(S) EXT
b0 00 d1 00 01 00 00 00 c2 4f 00 e0 00 00:40:44.892 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 e0 00 00:40:44.821 SMART READ DATA
42 00 00 00 01 00 00 f4 91 f7 c5 e0 00 00:40:44.821 READ VERIFY SECTOR(S) EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 23917 -
# 2 Short offline Completed without error 00% 23885 -
# 3 Short offline Completed without error 00% 23885 -
# 4 Short offline Aborted by host 10% 23880 -
# 5 Short offline Aborted by host 10% 23880 -
# 6 Short offline Aborted by host 10% 23874 -
# 7 Short offline Aborted by host 10% 23874 -
# 8 Short offline Aborted by host 10% 23872 -
# 9 Short offline Aborted by host 10% 23872 -
#10 Short offline Completed: read failure 50% 23872 4096365624
#11 Short offline Completed: read failure 90% 23872 4096357944
#12 Short offline Completed: read failure 10% 23872 4096357944
#13 Short offline Aborted by host 10% 23870 -
#14 Short offline Aborted by host 10% 23869 -
#15 Short offline Aborted by host 10% 23869 -
#16 Short offline Aborted by host 70% 23867 -
#17 Short offline Aborted by host 10% 23867 -
#18 Short offline Aborted by host 10% 23867 -
#19 Short offline Aborted by host 10% 23867 -
3 of 3 failed self-tests are outdated by newer successful extended offline self-test # 1
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 21/38 Celsius
Lifetime Min/Max Temperature: 10/51 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-5.19.10-300.fc37.x86_64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue
Device Model: WDC WD5000AAKX-00U6AA0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 15.01H15
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Sep 25 00:14:10 2022 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 8700) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 88) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3037) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 199 051 - 29423
3 Spin_Up_Time POS--K 144 142 021 - 3766
4 Start_Stop_Count -O--CK 096 096 000 - 4598
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 062 062 000 - 28317
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 096 096 000 - 4464
192 Power-Off_Retract_Count -O--CK 198 198 000 - 1715
193 Load_Cycle_Count -O--CK 200 200 000 - 2886
194 Temperature_Celsius -O---K 107 074 000 - 36
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 198 000 - 0
198 Offline_Uncorrectable ----CK 200 198 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 318832
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 47493 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 47493 [20] occurred at disk power-on lifetime: 28001 hours (1166 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 05 68 f9 d6 e5 00
Error: UNC at LBA = 0x0568f9d6 = 90765782
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
40 00 da 00 01 00 00 05 68 f9 d6 e5 00 00:12:17.264 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 05 68 f9 d5 e5 00 00:12:17.264 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 05 68 f9 d4 e5 00 00:12:17.264 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 05 68 f9 d3 e5 00 00:12:17.264 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 05 68 f9 d2 e5 00 00:12:17.264 READ VERIFY SECTOR(S)
Error 47492 [19] occurred at disk power-on lifetime: 28001 hours (1166 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 05 68 f9 d6 e5 00
Error: UNC at LBA = 0x0568f9d6 = 90765782
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
40 00 da 00 00 00 00 05 68 f9 00 e5 00 00:12:15.492 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 05 68 f8 00 e5 00 00:12:15.491 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 05 68 f7 00 e5 00 00:12:15.490 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 05 68 f6 00 e5 00 00:12:15.489 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 05 68 f5 00 e5 00 00:12:15.488 READ VERIFY SECTOR(S)
Error 47491 [18] occurred at disk power-on lifetime: 28001 hours (1166 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 00 2d f0 41 e0 00
Error: UNC at LBA = 0x002df041 = 3010625
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
40 00 da 00 01 00 00 00 2d f0 41 e0 00 00:06:21.078 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 00 2d f0 40 e0 00 00:06:21.078 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 00 2d f0 3f e0 00 00:06:21.078 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 00 2d f0 3e e0 00 00:06:21.078 READ VERIFY SECTOR(S)
40 00 da 00 01 00 00 00 2d f0 3d e0 00 00:06:21.078 READ VERIFY SECTOR(S)
Error 47490 [17] occurred at disk power-on lifetime: 28001 hours (1166 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 2d f0 41 e0 00
Error: UNC at LBA = 0x002df041 = 3010625
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
40 00 da 00 00 00 00 00 2d f0 00 e0 00 00:06:19.318 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 00 2d ef 00 e0 00 00:06:19.317 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 00 2d ee 00 e0 00 00:06:19.316 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 00 2d ed 00 e0 00 00:06:19.314 READ VERIFY SECTOR(S)
40 00 da 00 00 00 00 00 2d ec 00 e0 00 00:06:19.313 READ VERIFY SECTOR(S)
Error 47489 [16] occurred at disk power-on lifetime: 28000 hours (1166 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 0a c3 a2 40 00
Error: UNC at LBA = 0x000ac3a2 = 705442
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 a0 00 00 00 0a c3 a0 40 08 00:48:52.220 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 00:48:52.219 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 00:48:52.219 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 00:48:52.218 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 00:48:52.218 SET FEATURES [Set transfer mode]
Error 47488 [15] occurred at disk power-on lifetime: 28000 hours (1166 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 0a c3 a2 40 00
Error: UNC at LBA = 0x000ac3a2 = 705442
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 28 00 00 00 0a c3 a0 40 08 00:48:50.217 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 00:48:50.217 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 00:48:50.217 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 00:48:50.215 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 00:48:50.215 SET FEATURES [Set transfer mode]
Error 47487 [14] occurred at disk power-on lifetime: 28000 hours (1166 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 0a c3 a2 40 00
Error: UNC at LBA = 0x000ac3a2 = 705442
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 18 00 00 00 0a c3 a0 40 08 00:48:48.210 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 00:48:48.208 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 00:48:48.208 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 00:48:48.207 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 00:48:48.207 SET FEATURES [Set transfer mode]
Error 47486 [13] occurred at disk power-on lifetime: 28000 hours (1166 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 0a c3 a2 40 00
Error: UNC at LBA = 0x000ac3a2 = 705442
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 68 00 00 00 0a c3 a0 40 08 00:48:46.195 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 00:48:46.195 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 00:48:46.194 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 00:48:46.193 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 a0 08 00:48:46.193 SET FEATURES [Set transfer mode]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 28124 -
# 2 Conveyance offline Completed without error 00% 28123 -
# 3 Extended offline Completed without error 00% 28007 -
# 4 Short offline Completed without error 00% 28006 -
# 5 Conveyance offline Completed without error 00% 28001 -
# 6 Extended offline Completed: read failure 90% 28000 385227
1 of 1 failed self-tests are outdated by newer successful extended offline self-test # 1
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 25/39 Celsius
Lifetime Min/Max Temperature: 0/69 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (267)
Index Estimated Time Temperature Celsius
268 2022-09-24 16:17 39 ********************
269 2022-09-24 16:18 39 ********************
270 2022-09-24 16:19 39 ********************
271 2022-09-24 16:20 38 *******************
272 2022-09-24 16:21 38 *******************
273 2022-09-24 16:22 39 ********************
274 2022-09-24 16:23 38 *******************
... ..( 15 skipped). .. *******************
290 2022-09-24 16:39 38 *******************
291 2022-09-24 16:40 39 ********************
292 2022-09-24 16:41 39 ********************
293 2022-09-24 16:42 39 ********************
294 2022-09-24 16:43 38 *******************
295 2022-09-24 16:44 39 ********************
... ..( 27 skipped). .. ********************
323 2022-09-24 17:12 39 ********************
324 2022-09-24 17:13 38 *******************
325 2022-09-24 17:14 39 ********************
... ..( 2 skipped). .. ********************
328 2022-09-24 17:17 39 ********************
329 2022-09-24 17:18 38 *******************
330 2022-09-24 17:19 38 *******************
331 2022-09-24 17:20 39 ********************
... ..( 3 skipped). .. ********************
335 2022-09-24 17:24 39 ********************
336 2022-09-24 17:25 38 *******************
337 2022-09-24 17:26 39 ********************
... ..( 6 skipped). .. ********************
344 2022-09-24 17:33 39 ********************
345 2022-09-24 17:34 38 *******************
346 2022-09-24 17:35 39 ********************
347 2022-09-24 17:36 38 *******************
348 2022-09-24 17:37 39 ********************
349 2022-09-24 17:38 39 ********************
350 2022-09-24 17:39 38 *******************
351 2022-09-24 17:40 39 ********************
... ..( 33 skipped). .. ********************
385 2022-09-24 18:14 39 ********************
386 2022-09-24 18:15 38 *******************
387 2022-09-24 18:16 38 *******************
388 2022-09-24 18:17 39 ********************
389 2022-09-24 18:18 39 ********************
390 2022-09-24 18:19 39 ********************
391 2022-09-24 18:20 38 *******************
... ..( 17 skipped). .. *******************
409 2022-09-24 18:38 38 *******************
410 2022-09-24 18:39 37 ******************
411 2022-09-24 18:40 38 *******************
412 2022-09-24 18:41 38 *******************
413 2022-09-24 18:42 37 ******************
414 2022-09-24 18:43 38 *******************
415 2022-09-24 18:44 38 *******************
416 2022-09-24 18:45 38 *******************
417 2022-09-24 18:46 37 ******************
... ..( 2 skipped). .. ******************
420 2022-09-24 18:49 37 ******************
421 2022-09-24 18:50 38 *******************
422 2022-09-24 18:51 38 *******************
423 2022-09-24 18:52 37 ******************
... ..( 68 skipped). .. ******************
14 2022-09-24 20:01 37 ******************
15 2022-09-24 20:02 38 *******************
16 2022-09-24 20:03 37 ******************
... ..( 4 skipped). .. ******************
21 2022-09-24 20:08 37 ******************
22 2022-09-24 20:09 38 *******************
23 2022-09-24 20:10 37 ******************
... ..( 33 skipped). .. ******************
57 2022-09-24 20:44 37 ******************
58 2022-09-24 20:45 36 *****************
... ..( 24 skipped). .. *****************
83 2022-09-24 21:10 36 *****************
84 2022-09-24 21:11 37 ******************
... ..( 2 skipped). .. ******************
87 2022-09-24 21:14 37 ******************
88 2022-09-24 21:15 38 *******************
... ..( 9 skipped). .. *******************
98 2022-09-24 21:25 38 *******************
99 2022-09-24 21:26 39 ********************
... ..( 84 skipped). .. ********************
184 2022-09-24 22:51 39 ********************
185 2022-09-24 22:52 38 *******************
... ..( 6 skipped). .. *******************
192 2022-09-24 22:59 38 *******************
193 2022-09-24 23:00 39 ********************
... ..( 73 skipped). .. ********************
267 2022-09-25 00:14 39 ********************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 29 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 31052 Vendor specific