/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-arch1-1] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Samsung SSD 990 PRO 2TB
Serial Number: --
Firmware Version: 3B2QJXD7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 2,000,398,934,016 [2.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 2.0
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,000,398,934,016 [2.00 TB]
Namespace 1 Utilization: 414,597,750,784 [414 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Mon Nov 27 17:37:08 2023 CET
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0055): Comp DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x2f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Log0_FISE_MI
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 82 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.39W - - 0 0 0 0 0 0
1 + 9.39W - - 1 1 1 1 0 200
2 + 9.39W - - 2 2 2 2 0 1000
3 - 0.0400W - - 3 3 3 3 2000 1200
4 - 0.0050W - - 4 4 4 4 500 9500
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 43 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 1%
Data Units Read: 18,664,706 [9.55 TB]
Data Units Written: 21,898,498 [11.2 TB]
Host Read Commands: 269,007,072
Host Write Commands: 569,764,526
Controller Busy Time: 2,310
Power Cycles: 122
Power On Hours: 271
Unsafe Shutdowns: 18
Media and Data Integrity Errors: 0
Error Information Log Entries: 2
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 43 Celsius
Temperature Sensor 2: 52 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
No Errors Logged
Read Self-test Log failed: Invalid Field in Command (0x002)
/dev/nvme1n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-arch1-1] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Samsung SSD 970 EVO Plus 1TB
Serial Number: --
Firmware Version: 2B2QEXM7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 1,000,204,886,016 [1.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 4
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB]
Namespace 1 Utilization: 839,696,498,688 [839 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Mon Nov 27 17:37:08 2023 CET
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.80W - - 0 0 0 0 0 0
1 + 6.00W - - 1 1 1 1 0 0
2 + 3.40W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 210 1200
4 - 0.0100W - - 4 4 4 4 2000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 46%
Data Units Read: 138,727,956 [71.0 TB]
Data Units Written: 469,656,019 [240 TB]
Host Read Commands: 2,214,395,845
Host Write Commands: 18,798,841,025
Controller Busy Time: 134,380
Power Cycles: 1,195
Power On Hours: 23,270
Unsafe Shutdowns: 143
Media and Data Integrity Errors: 0
Error Information Log Entries: 4,089
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 37 Celsius
Temperature Sensor 2: 36 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 4089 0 0x0014 0x4004 - 0 0 - Invalid Field in Command
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged
/dev/sda
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-arch1-1] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST4000VN006-3CW104
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: SC60
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Nov 27 17:37:08 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 453) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x70bd) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 065 006 - 543195
3 Spin_Up_Time PO---- 096 095 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 564
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
7 Seek_Error_Rate POSR-- 068 060 045 - 6416872
9 Power_On_Hours -O--CK 096 096 000 - 3738
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 340
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 069 058 040 - 31 (Min/Max 26/31)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 28
193 Load_Cycle_Count -O--CK 100 100 000 - 1415
194 Temperature_Celsius -O---K 031 042 000 - 31 (0 24 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 100 065 000 - 543195
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
240 Head_Flying_Hours ------ 100 253 000 - 880 (67 120 0)
241 Total_LBAs_Written ------ 100 253 000 - 13967690933
242 Total_LBAs_Read ------ 100 253 000 - 6073892997
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0c GPL R/O 2048 Pending Defects log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 512 Current Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 24 Device vendor specific log
0xa2 GPL VS 8160 Device vendor specific log
0xa6 GPL VS 192 Device vendor specific log
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 9048 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL,SL VS 16 Device vendor specific log
0xc3 GPL,SL VS 8 Device vendor specific log
0xc4 GPL,SL VS 24 Device vendor specific log
0xd1 GPL VS 264 Device vendor specific log
0xd3 GPL VS 1920 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 26/31 Celsius
Lifetime Min/Max Temperature: 24/42 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 3 minutes
Temperature Logging Interval: 94 minutes
Min/Max recommended Temperature: 1/61 Celsius
Min/Max Temperature Limit: 2/60 Celsius
Temperature History Size (Index): 128 (97)
Index Estimated Time Temperature Celsius
98 2023-11-19 10:38 27 ********
99 2023-11-19 12:12 ? -
100 2023-11-19 13:46 33 **************
101 2023-11-19 15:20 ? -
102 2023-11-19 16:54 27 ********
103 2023-11-19 18:28 ? -
104 2023-11-19 20:02 27 ********
105 2023-11-19 21:36 ? -
106 2023-11-19 23:10 29 **********
107 2023-11-20 00:44 ? -
108 2023-11-20 02:18 34 ***************
109 2023-11-20 03:52 ? -
110 2023-11-20 05:26 28 *********
111 2023-11-20 07:00 ? -
112 2023-11-20 08:34 25 ******
113 2023-11-20 10:08 ? -
114 2023-11-20 11:42 29 **********
115 2023-11-20 13:16 ? -
116 2023-11-20 14:50 26 *******
117 2023-11-20 16:24 ? -
118 2023-11-20 17:58 26 *******
119 2023-11-20 19:32 ? -
120 2023-11-20 21:06 32 *************
121 2023-11-20 22:40 ? -
122 2023-11-21 00:14 32 *************
123 2023-11-21 01:48 ? -
124 2023-11-21 03:22 27 ********
125 2023-11-21 04:56 ? -
126 2023-11-21 06:30 28 *********
127 2023-11-21 08:04 ? -
0 2023-11-21 09:38 31 ************
1 2023-11-21 11:12 ? -
2 2023-11-21 12:46 35 ****************
3 2023-11-21 14:20 ? -
4 2023-11-21 15:54 34 ***************
5 2023-11-21 17:28 ? -
6 2023-11-21 19:02 27 ********
7 2023-11-21 20:36 ? -
8 2023-11-21 22:10 27 ********
9 2023-11-21 23:44 ? -
10 2023-11-22 01:18 26 *******
11 2023-11-22 02:52 ? -
12 2023-11-22 04:26 26 *******
13 2023-11-22 06:00 ? -
14 2023-11-22 07:34 26 *******
15 2023-11-22 09:08 ? -
16 2023-11-22 10:42 27 ********
17 2023-11-22 12:16 ? -
18 2023-11-22 13:50 33 **************
19 2023-11-22 15:24 ? -
20 2023-11-22 16:58 26 *******
21 2023-11-22 18:32 ? -
22 2023-11-22 20:06 27 ********
23 2023-11-22 21:40 ? -
24 2023-11-22 23:14 27 ********
25 2023-11-23 00:48 ? -
26 2023-11-23 02:22 26 *******
27 2023-11-23 03:56 ? -
28 2023-11-23 05:30 26 *******
29 2023-11-23 07:04 ? -
30 2023-11-23 08:38 26 *******
31 2023-11-23 10:12 ? -
32 2023-11-23 11:46 34 ***************
33 2023-11-23 13:20 ? -
34 2023-11-23 14:54 34 ***************
35 2023-11-23 16:28 ? -
36 2023-11-23 18:02 26 *******
37 2023-11-23 19:36 ? -
38 2023-11-23 21:10 33 **************
39 2023-11-23 22:44 ? -
40 2023-11-24 00:18 26 *******
41 2023-11-24 01:52 ? -
42 2023-11-24 03:26 35 ****************
43 2023-11-24 05:00 ? -
44 2023-11-24 06:34 26 *******
45 2023-11-24 08:08 ? -
46 2023-11-24 09:42 26 *******
47 2023-11-24 11:16 ? -
48 2023-11-24 12:50 26 *******
49 2023-11-24 14:24 ? -
50 2023-11-24 15:58 33 **************
51 2023-11-24 17:32 ? -
52 2023-11-24 19:06 34 ***************
53 2023-11-24 20:40 ? -
54 2023-11-24 22:14 26 *******
55 2023-11-24 23:48 ? -
56 2023-11-25 01:22 33 **************
57 2023-11-25 02:56 ? -
58 2023-11-25 04:30 28 *********
59 2023-11-25 06:04 ? -
60 2023-11-25 07:38 34 ***************
61 2023-11-25 09:12 ? -
62 2023-11-25 10:46 32 *************
63 2023-11-25 12:20 36 *****************
64 2023-11-25 13:54 ? -
65 2023-11-25 15:28 25 ******
66 2023-11-25 17:02 34 ***************
67 2023-11-25 18:36 34 ***************
68 2023-11-25 20:10 33 **************
69 2023-11-25 21:44 32 *************
... ..( 3 skipped). .. *************
73 2023-11-26 04:00 32 *************
74 2023-11-26 05:34 36 *****************
75 2023-11-26 07:08 38 *******************
76 2023-11-26 08:42 38 *******************
77 2023-11-26 10:16 37 ******************
78 2023-11-26 11:50 37 ******************
79 2023-11-26 13:24 33 **************
80 2023-11-26 14:58 32 *************
81 2023-11-26 16:32 35 ****************
82 2023-11-26 18:06 37 ******************
83 2023-11-26 19:40 37 ******************
84 2023-11-26 21:14 ? -
85 2023-11-26 22:48 25 ******
86 2023-11-27 00:22 ? -
87 2023-11-27 01:56 33 **************
88 2023-11-27 03:30 ? -
89 2023-11-27 05:04 26 *******
90 2023-11-27 06:38 ? -
91 2023-11-27 08:12 25 ******
92 2023-11-27 09:46 ? -
93 2023-11-27 11:20 26 *******
94 2023-11-27 12:54 31 ************
95 2023-11-27 14:28 26 *******
96 2023-11-27 16:02 27 ********
97 2023-11-27 17:36 31 ************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 340 --- Lifetime Power-On Resets
0x01 0x010 4 3738 --- Power-on Hours
0x01 0x018 6 13967694181 --- Logical Sectors Written
0x01 0x020 6 27443407 --- Number of Write Commands
0x01 0x028 6 6073803364 --- Logical Sectors Read
0x01 0x030 6 9500545 --- Number of Read Commands
0x01 0x038 6 - --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 3442 --- Spindle Motor Power-on Hours
0x03 0x010 4 880 --- Head Flying Hours
0x03 0x018 4 1415 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
0x03 0x040 4 28 --- Number of High Priority Unload Events
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 31 --- Current Temperature
0x05 0x010 1 31 --- Average Short Term Temperature
0x05 0x018 1 32 --- Average Long Term Temperature
0x05 0x020 1 42 --- Highest Temperature
0x05 0x028 1 24 --- Lowest Temperature
0x05 0x030 1 39 --- Highest Average Short Term Temperature
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
0x05 0x040 1 37 --- Highest Average Long Term Temperature
0x05 0x048 1 30 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 928 --- Number of Hardware Resets
0x06 0x010 4 32 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c)
No Defects Logged
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
Seagate FARM log (GP Log 0xa6) supported [try: -l farm]
/dev/sdb
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-arch1-1] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint F2 EG
Device Model: SAMSUNG HD103SI
Serial Number: --
LU WWN Device Id: 5 0024e9 ...
Firmware Version: 1AG01118
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
Local Time is: Mon Nov 27 17:37:08 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (12515) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 209) minutes.
Conveyance self-test routine
recommended polling time: ( 22) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 072 051 - 90
3 Spin_Up_Time POS--- 086 086 011 - 5100
4 Start_Stop_Count -O--CK 085 085 000 - 15098
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
7 Seek_Error_Rate POSR-- 100 100 051 - 0
8 Seek_Time_Performance P-S--K 100 100 015 - 0
9 Power_On_Hours -O--CK 091 091 000 - 42957
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 000 - 0
12 Power_Cycle_Count -O--CK 096 096 000 - 3648
13 Read_Soft_Error_Rate -OSR-- 100 072 000 - 90
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 1288
188 Command_Timeout -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 077 058 000 - 23 (Min/Max 17/23)
194 Temperature_Celsius -O---K 075 055 000 - 25 (Min/Max 17/26)
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 105424
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x04 GPL R/O 2 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 2 Streaming performance log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 630 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 630 [5] occurred at disk power-on lifetime: 37105 hours (1546 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 08 00 00 00 e0 2b 17 40 00 1d+03:05:08.590 WRITE FPDMA QUEUED
61 00 00 00 08 00 00 00 5b 17 4f 40 00 1d+03:05:08.390 WRITE FPDMA QUEUED
61 00 00 00 08 00 00 00 de 35 1f 40 00 1d+03:05:08.390 WRITE FPDMA QUEUED
60 00 00 00 03 00 00 00 e1 64 8f 40 00 1d+03:05:08.390 READ FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 a0 00 1d+03:05:08.390 FLUSH CACHE EXT
Error 629 [4] occurred at disk power-on lifetime: 37105 hours (1546 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 03 00 00 00 e1 64 8f 40 00 1d+03:05:05.530 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 5b 17 57 40 00 1d+03:05:05.530 WRITE FPDMA QUEUED
61 00 00 00 08 00 00 00 dc b9 0f 40 00 1d+03:05:05.530 WRITE FPDMA QUEUED
61 00 00 00 f8 00 00 00 5b 3e 7f 40 00 1d+03:05:05.530 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 1d+03:05:05.530 READ LOG EXT
Error 628 [3] occurred at disk power-on lifetime: 37105 hours (1546 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 f8 00 00 00 5b 3e 7f 40 00 1d+03:05:02.990 WRITE FPDMA QUEUED
60 00 00 00 03 00 00 00 e1 64 8f 40 00 1d+03:05:02.790 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 dc b8 f7 40 00 1d+03:05:02.790 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 1d+03:05:02.790 READ LOG EXT
Error 627 [2] occurred at disk power-on lifetime: 37105 hours (1546 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 08 00 00 00 dc b8 f7 40 00 1d+03:05:00.740 WRITE FPDMA QUEUED
60 00 00 00 03 00 00 00 e1 64 8f 40 00 1d+03:05:00.240 READ FPDMA QUEUED
60 00 00 00 05 00 00 00 e1 64 87 40 00 1d+03:05:00.240 READ FPDMA QUEUED
60 00 00 00 03 00 00 00 e1 64 7f 40 00 1d+03:05:00.240 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 73 8c f7 40 00 1d+03:05:00.240 READ FPDMA QUEUED
Error 626 [1] occurred at disk power-on lifetime: 37103 hours (1545 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 07 a0 24 04 40 00 at LBA = 0x07a02404 = 127935492
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 08 00 00 00 9c 1b 6f 40 00 1d+00:49:56.290 WRITE FPDMA QUEUED
60 00 00 00 40 00 00 00 a0 23 ff 40 00 1d+00:49:55.800 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 21 5c 9f 40 00 1d+00:49:55.790 READ FPDMA QUEUED
60 00 00 00 05 00 00 00 a0 23 f7 40 00 1d+00:49:55.790 READ FPDMA QUEUED
60 00 00 00 23 00 00 00 a0 23 cf 40 00 1d+00:49:55.790 READ FPDMA QUEUED
Error 625 [0] occurred at disk power-on lifetime: 37088 hours (1545 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 03 00 00 00 e1 64 8f 40 00 10:21:37.130 READ FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 a0 00 10:21:37.130 FLUSH CACHE EXT
ec 00 00 00 00 00 00 00 00 00 00 a0 00 10:21:37.110 IDENTIFY DEVICE
61 00 00 00 08 00 00 00 5b 17 57 40 00 10:21:37.110 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 10:21:37.110 READ LOG EXT
Error 624 [7] occurred at disk power-on lifetime: 37088 hours (1545 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 08 00 00 00 5b 17 57 40 00 10:21:34.520 WRITE FPDMA QUEUED
60 00 00 00 03 00 00 00 e1 64 8f 40 00 10:21:34.520 READ FPDMA QUEUED
61 00 00 00 b8 00 00 00 5b b5 e7 40 00 10:21:34.520 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 10:21:34.520 READ LOG EXT
Error 623 [6] occurred at disk power-on lifetime: 37088 hours (1545 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 42 00 00 00 00 10 e1 64 90 40 00 at LBA = 0x10e16490 = 283206800
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 b8 00 00 00 5b b5 e7 40 00 10:21:32.500 WRITE FPDMA QUEUED
60 00 00 00 03 00 00 00 e1 64 8f 40 00 10:21:32.500 READ FPDMA QUEUED
61 00 00 00 40 00 00 00 5b 17 d7 40 00 10:21:32.500 WRITE FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 10:21:32.500 READ LOG EXT
SMART Extended Self-test Log Version: 1 (2 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 25 Celsius
Power Cycle Min/Max Temperature: --/26 Celsius
Lifetime Min/Max Temperature: --/45 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: -4/72 Celsius
Min/Max Temperature Limit: -9/77 Celsius
Temperature History Size (Index): 128 (91)
Index Estimated Time Temperature Celsius
92 2023-11-27 15:30 24 *****
... ..( 41 skipped). .. *****
6 2023-11-27 16:12 24 *****
7 2023-11-27 16:13 25 ******
8 2023-11-27 16:14 24 *****
... ..( 7 skipped). .. *****
16 2023-11-27 16:22 24 *****
17 2023-11-27 16:23 25 ******
... ..( 73 skipped). .. ******
91 2023-11-27 17:37 25 ******
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
ATA_READ_LOG_EXT (addr=0x04:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters
Read Device Statistics page 0x00 failed
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 8355 Transition from drive PhyRdy to drive PhyNRdy
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC