/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.0-101-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 850 EVO 120GB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: EMT02B6Q
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Mar 20 12:22:34 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 3468
12 Power_Cycle_Count -O--CK 096 096 000 - 3415
177 Wear_Leveling_Count PO--C- 097 097 000 - 46
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 067 035 000 - 33
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 099 099 000 - 29
235 POR_Recovery_Count -O--C- 099 099 000 - 49
241 Total_LBAs_Written -O--CK 099 099 000 - 11965562959
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 0 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
255 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 1 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: SCT command executing in background (5)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 30/40 Celsius
Lifetime Min/Max Temperature: 0/70 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (5)
Index Estimated Time Temperature Celsius
6 2024-03-19 15:10 ? -
... ..(120 skipped). .. -
127 2024-03-20 11:20 ? -
0 2024-03-20 11:30 40 *********************
1 2024-03-20 11:40 33 **************
2 2024-03-20 11:50 30 ***********
3 2024-03-20 12:00 33 **************
4 2024-03-20 12:10 34 ***************
5 2024-03-20 12:20 33 **************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdc
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.0-101-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 5400.6
Device Model: ST9500325AS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: 0002BSM1
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 1.5 Gb/s
Local Time is: Wed Mar 20 12:22:34 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 142) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 148038944
3 Spin_Up_Time PO---- 098 098 000 - 0
4 Start_Stop_Count -O--CK 093 093 020 - 7302
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 088 060 030 - 800789654
9 Power_On_Hours -O--CK 094 094 000 - 5600
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 096 037 020 - 4693
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 080 080 000 - 20
188 Command_Timeout -O--CK 100 098 000 - 12885098505
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 072 050 045 - 28 (Min/Max 20/28)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 5
192 Power-Off_Retract_Count -O--CK 099 099 000 - 2940
193 Load_Cycle_Count -O--CK 092 092 000 - 16973
194 Temperature_Celsius -O---K 028 050 000 - 28 (0 15 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 046 026 000 - 148038944
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 65 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xb0 GPL VS 2864 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 20
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 20 [19] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:15.209 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 13 19 40 00 01:23:15.088 READ DMA EXT
25 00 d0 00 40 00 00 1b 6c 12 d9 40 00 01:23:12.810 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 e1 40 00 01:23:12.754 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:10.345 READ DMA EXT
Error 19 [18] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 40 00 00 1b 6c 12 d9 40 00 01:23:12.810 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 e1 40 00 01:23:12.754 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:10.345 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:08.069 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d1 40 00 01:23:08.066 READ DMA EXT
Error 18 [17] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:10.345 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:08.069 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d1 40 00 01:23:08.066 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d1 40 00 01:23:08.058 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 c9 40 00 01:23:08.055 READ DMA EXT
Error 17 [16] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 08 00 00 1b 6c 12 d9 40 00 01:23:08.069 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d1 40 00 01:23:08.066 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 d1 40 00 01:23:08.058 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 c9 40 00 01:23:08.055 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 c9 40 00 01:23:08.054 READ DMA EXT
Error 16 [15] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 80 00 00 1b 6c 12 89 40 00 01:23:05.554 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 81 40 00 01:23:05.551 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 81 40 00 01:23:05.550 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 79 40 00 01:23:05.550 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 12 79 40 00 01:23:05.549 READ DMA EXT
Error 15 [14] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 80 00 00 1b 6c 12 09 40 00 01:23:02.968 READ DMA EXT
25 00 d0 00 80 00 00 1b 6c 11 89 40 00 01:23:02.962 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 11 31 40 00 01:23:02.959 READ DMA EXT
25 00 d0 00 58 00 00 1b 6c 11 31 40 00 01:23:02.957 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 10 b1 40 00 01:23:02.956 READ DMA EXT
Error 14 [13] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 80 00 00 1b 6c 10 09 40 00 01:23:00.488 READ DMA EXT
25 00 d0 00 80 00 00 1b 6c 0f 89 40 00 01:23:00.482 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 0f 09 40 00 01:23:00.479 READ DMA EXT
25 00 d0 00 80 00 00 1b 6c 0f 09 40 00 01:23:00.477 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 0e 89 40 00 01:23:00.476 READ DMA EXT
Error 13 [12] occurred at disk power-on lifetime: 5251 hours (218 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1b 6c 12 de 00 00
Error: UNC at LBA = 0x1b6c12de = 460067550
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 d0 00 80 00 00 1b 6c 0e 09 40 00 01:22:57.943 READ DMA EXT
25 00 d0 00 80 00 00 1b 6c 0d 89 40 00 01:22:57.936 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 0d 11 40 00 01:22:57.933 READ DMA EXT
25 00 d0 00 78 00 00 1b 6c 0d 11 40 00 01:22:57.931 READ DMA EXT
25 00 d0 00 08 00 00 1b 6c 0c 91 40 00 01:22:57.930 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 20/28 Celsius
Lifetime Min/Max Temperature: 15/50 Celsius
Under/Over Temperature Limit Count: 0/13
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (22)
Index Estimated Time Temperature Celsius
23 2024-03-20 10:15 23 ****
24 2024-03-20 10:16 25 ******
25 2024-03-20 10:17 ? -
26 2024-03-20 10:18 21 **
27 2024-03-20 10:19 23 ****
28 2024-03-20 10:20 24 *****
29 2024-03-20 10:21 25 ******
30 2024-03-20 10:22 25 ******
31 2024-03-20 10:23 26 *******
32 2024-03-20 10:24 ? -
33 2024-03-20 10:25 22 ***
34 2024-03-20 10:26 24 *****
35 2024-03-20 10:27 25 ******
36 2024-03-20 10:28 26 *******
37 2024-03-20 10:29 26 *******
38 2024-03-20 10:30 26 *******
39 2024-03-20 10:31 27 ********
40 2024-03-20 10:32 28 *********
41 2024-03-20 10:33 28 *********
42 2024-03-20 10:34 26 *******
43 2024-03-20 10:35 27 ********
44 2024-03-20 10:36 ? -
45 2024-03-20 10:37 20 *
46 2024-03-20 10:38 24 *****
47 2024-03-20 10:39 25 ******
48 2024-03-20 10:40 ? -
49 2024-03-20 10:41 20 *
50 2024-03-20 10:42 21 **
51 2024-03-20 10:43 21 **
52 2024-03-20 10:44 22 ***
53 2024-03-20 10:45 23 ****
54 2024-03-20 10:46 24 *****
55 2024-03-20 10:47 24 *****
56 2024-03-20 10:48 25 ******
57 2024-03-20 10:49 26 *******
58 2024-03-20 10:50 26 *******
59 2024-03-20 10:51 27 ********
60 2024-03-20 10:52 27 ********
61 2024-03-20 10:53 28 *********
62 2024-03-20 10:54 28 *********
63 2024-03-20 10:55 28 *********
64 2024-03-20 10:56 29 **********
65 2024-03-20 10:57 29 **********
66 2024-03-20 10:58 30 ***********
... ..( 2 skipped). .. ***********
69 2024-03-20 11:01 30 ***********
70 2024-03-20 11:02 31 ************
... ..( 2 skipped). .. ************
73 2024-03-20 11:05 31 ************
74 2024-03-20 11:06 32 *************
... ..( 5 skipped). .. *************
80 2024-03-20 11:12 32 *************
81 2024-03-20 11:13 31 ************
82 2024-03-20 11:14 31 ************
83 2024-03-20 11:15 32 *************
84 2024-03-20 11:16 32 *************
85 2024-03-20 11:17 31 ************
86 2024-03-20 11:18 31 ************
87 2024-03-20 11:19 31 ************
88 2024-03-20 11:20 29 **********
... ..( 3 skipped). .. **********
92 2024-03-20 11:24 29 **********
93 2024-03-20 11:25 ? -
94 2024-03-20 11:26 19 -
95 2024-03-20 11:27 20 *
96 2024-03-20 11:28 23 ****
97 2024-03-20 11:29 25 ******
98 2024-03-20 11:30 26 *******
99 2024-03-20 11:31 26 *******
100 2024-03-20 11:32 25 ******
101 2024-03-20 11:33 ? -
102 2024-03-20 11:34 20 *
103 2024-03-20 11:35 22 ***
104 2024-03-20 11:36 22 ***
105 2024-03-20 11:37 24 *****
106 2024-03-20 11:38 25 ******
107 2024-03-20 11:39 ? -
108 2024-03-20 11:40 20 *
109 2024-03-20 11:41 22 ***
110 2024-03-20 11:42 23 ****
111 2024-03-20 11:43 23 ****
112 2024-03-20 11:44 24 *****
113 2024-03-20 11:45 24 *****
114 2024-03-20 11:46 24 *****
115 2024-03-20 11:47 25 ******
116 2024-03-20 11:48 25 ******
117 2024-03-20 11:49 26 *******
118 2024-03-20 11:50 25 ******
119 2024-03-20 11:51 ? -
120 2024-03-20 11:52 19 -
121 2024-03-20 11:53 22 ***
122 2024-03-20 11:54 23 ****
123 2024-03-20 11:55 23 ****
124 2024-03-20 11:56 ? -
125 2024-03-20 11:57 20 *
126 2024-03-20 11:58 23 ****
127 2024-03-20 11:59 25 ******
0 2024-03-20 12:00 ? -
1 2024-03-20 12:01 19 -
2 2024-03-20 12:02 22 ***
3 2024-03-20 12:03 24 *****
4 2024-03-20 12:04 24 *****
5 2024-03-20 12:05 25 ******
6 2024-03-20 12:06 25 ******
7 2024-03-20 12:07 26 *******
8 2024-03-20 12:08 25 ******
9 2024-03-20 12:09 ? -
10 2024-03-20 12:10 20 *
11 2024-03-20 12:11 21 **
12 2024-03-20 12:12 24 *****
13 2024-03-20 12:13 24 *****
14 2024-03-20 12:14 25 ******
15 2024-03-20 12:15 26 *******
16 2024-03-20 12:16 26 *******
17 2024-03-20 12:17 26 *******
18 2024-03-20 12:18 27 ********
19 2024-03-20 12:19 27 ********
20 2024-03-20 12:20 28 *********
21 2024-03-20 12:21 28 *********
22 2024-03-20 12:22 28 *********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS