/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar
Device Model: WDC WD400BB-22DEA0
Serial Number: --
Firmware Version: 05.03E05
User Capacity: 40 019 582 464 bytes [40,0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-5 (minor revision not indicated)
Local Time is: Thu Apr 27 01:07:30 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 39) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete Offline
data collection: ( 1506) seconds.
Offline data collection
capabilities: (0x3b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 28) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 198 051 - 0
3 Spin_Up_Time POS--- 095 093 021 - 2625
4 Start_Stop_Count -O--CK 091 091 040 - 9406
5 Reallocated_Sector_Ct PO--CK 198 198 140 - 32
7 Seek_Error_Rate PO-R-- 100 253 051 - 0
9 Power_On_Hours -O--CK 073 073 000 - 19986
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 093 093 000 - 7762
196 Reallocated_Event_Count -O--CK 192 192 000 - 8
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable -O--C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 201
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: scsi error badly formed scsi parameters
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 3283 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3283 occurred at disk power-on lifetime: 324 hours (13 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 2e ad a8 e4
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f9 00 01 2e ad a8 e4 08 07:48:07.950 SET MAX ADDRESS [OBS-6]
f8 00 00 2e ad a8 e0 08 07:48:07.950 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 00 2e ad a8 e4 08 07:48:07.800 SET MAX ADDRESS [OBS-6]
f8 00 01 2e ad a8 e0 08 07:48:07.800 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 01 2e ad a8 e4 08 07:48:05.700 SET MAX ADDRESS [OBS-6]
Error 3282 occurred at disk power-on lifetime: 324 hours (13 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 2e ad a8 e4
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f9 00 01 2e ad a8 e4 08 07:48:05.700 SET MAX ADDRESS [OBS-6]
f8 00 00 2e ad a8 e0 08 07:48:05.700 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 00 2e ad a8 e4 08 07:48:05.550 SET MAX ADDRESS [OBS-6]
f8 00 01 6f b5 a8 e0 08 07:48:05.550 READ NATIVE MAX ADDRESS [OBS-ACS-3]
c4 00 01 6f b5 a8 e4 00 07:48:05.450 READ MULTIPLE
Error 3281 occurred at disk power-on lifetime: 317 hours (13 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 2e ad a8 e4
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f9 00 01 2e ad a8 e4 08 00:16:13.100 SET MAX ADDRESS [OBS-6]
f8 00 00 2e ad a8 e0 08 00:16:13.100 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 00 2e ad a8 e4 08 00:16:13.000 SET MAX ADDRESS [OBS-6]
f8 00 01 2e ad a8 e0 08 00:16:13.000 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 01 2e ad a8 e4 08 00:16:10.850 SET MAX ADDRESS [OBS-6]
Error 3280 occurred at disk power-on lifetime: 317 hours (13 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 2e ad a8 e4
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f9 00 01 2e ad a8 e4 08 00:16:10.850 SET MAX ADDRESS [OBS-6]
f8 00 00 2e ad a8 e0 08 00:16:10.850 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 00 2e ad a8 e4 08 00:16:10.750 SET MAX ADDRESS [OBS-6]
f8 00 01 6f b5 a8 e0 08 00:16:10.750 READ NATIVE MAX ADDRESS [OBS-ACS-3]
c4 00 01 6f b5 a8 e4 00 00:16:10.600 READ MULTIPLE
Error 3279 occurred at disk power-on lifetime: 317 hours (13 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 2e ad a8 e4
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f9 00 01 2e ad a8 e4 08 03:43:52.700 SET MAX ADDRESS [OBS-6]
f8 00 00 2e ad a8 e0 08 03:43:52.700 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 00 2e ad a8 e4 08 03:43:52.600 SET MAX ADDRESS [OBS-6]
f8 00 01 2e ad a8 e0 08 03:43:52.600 READ NATIVE MAX ADDRESS [OBS-ACS-3]
f9 00 01 2e ad a8 e4 08 03:43:50.500 SET MAX ADDRESS [OBS-6]
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 70% 315 -
# 2 Short offline Completed: read failure 90% 182 6293498
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11) not supported
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar 7K80
Device Model: HDS728080PLAT20
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: PF2OA21B
User Capacity: 82 347 195 904 bytes [82,3 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
Local Time is: Thu Apr 27 01:07:31 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1828) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 31) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 158 158 050 - 213
3 Spin_Up_Time POS--- 103 103 024 - 193 (Average 194)
4 Start_Stop_Count -O--C- 098 098 000 - 8320
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 136 136 020 - 31
9 Power_On_Hours -O--C- 097 097 000 - 21260
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 7244
192 Power-Off_Retract_Count -O--CK 093 093 050 - 8735
193 Load_Cycle_Count -O--C- 093 093 050 - 8735
194 Temperature_Celsius -O---- 125 125 000 - 44 (Min/Max -4/75)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 9
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
Device Error Count: 443 (device log contains only the most recent 4 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 443 [2] occurred at disk power-on lifetime: 17325 hours (721 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 09 96 23 3e f9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 00 09 96 23 3e f9 00 00:09:16.500 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 09 96 23 3e f0 00 00:09:16.500 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 00 09 96 23 3e f9 00 00:09:16.400 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 00 09 96 23 3e f0 00 00:09:16.400 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 00 09 96 23 3e f9 00 00:09:14.300 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 442 [1] occurred at disk power-on lifetime: 17325 hours (721 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 09 96 23 3e f9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 00 09 96 23 3e f9 00 00:09:14.300 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 09 96 23 3e f0 00 00:09:14.300 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 00 09 96 23 3e f9 00 00:09:14.200 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 09 96 2b 7f f0 00 00:09:14.200 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 00 09 96 2b 7f f0 00 00:09:14.000 READ MULTIPLE EXT
Error 441 [0] occurred at disk power-on lifetime: 17097 hours (712 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 09 96 23 3e e9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 00 09 96 23 3e e9 00 00:09:19.900 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 09 96 23 3e e0 00 00:09:19.900 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 00 09 96 23 3e e9 00 00:09:19.800 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 00 09 96 23 3e e0 00 00:09:19.800 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 00 09 96 23 3e e9 00 00:09:17.700 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 440 [3] occurred at disk power-on lifetime: 17097 hours (712 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 09 96 23 3e e9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 00 09 96 23 3e e9 00 00:09:17.700 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 09 96 23 3e e0 00 00:09:17.700 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 00 09 96 23 3e e9 00 00:09:17.600 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 09 96 2b 7f e0 00 00:09:17.600 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 00 09 96 2b 7f e0 00 00:09:17.400 READ MULTIPLE EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 50% 21250 -
# 2 Short offline Completed without error 00% 15722 -
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11) not supported