Probe #93fb65f119 of ASRock FM2A75 Pro4 Desktop Computer

Log: smartctl

/dev/sda === START OF INFORMATION SECTION === Device Model: KINGMAX SSD 120GB Serial Number: -- Firmware Version: M1024E User Capacity: 120 034 123 776 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s Local Time is: Thu Dec 7 20:27:00 2017 +05 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Disabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x75) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 3) minutes. Extended self-test routine recommended polling time: ( 40) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate ------ 100 100 000 - 0 5 Reallocated_Sector_Ct ------ 100 100 000 - 0 9 Power_On_Hours ------ 100 100 000 - 350 12 Power_Cycle_Count ------ 100 100 000 - 1455 192 Power-Off_Retract_Count ------ 100 100 000 - 58 194 Temperature_Celsius ------ 100 100 000 - 43 195 Hardware_ECC_Recovered ------ 100 100 000 - 37057 196 Reallocated_Event_Count ------ 092 092 046 - 0 199 UDMA_CRC_Error_Count ------ 100 100 050 - 8 160 Unknown_Attribute ------ 100 100 000 - 0 161 Unknown_Attribute ------ 100 100 000 - 92 163 Unknown_Attribute ------ 100 100 000 - 14 164 Unknown_Attribute ------ 100 100 000 - 80152 165 Unknown_Attribute ------ 100 100 050 - 138 166 Unknown_Attribute ------ 100 100 050 - 36 167 Unknown_Attribute ------ 100 100 000 - 79 241 Total_LBAs_Written ------ 100 100 000 - 76164 242 Total_LBAs_Read ------ 100 100 000 - 67283 168 Unknown_Attribute ------ 100 100 000 - 3000 169 Unknown_Attribute ------ 100 100 000 - 99 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x02 GPL,SL R/O 1 Comprehensive SMART error log 0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 1 Extended self-test log 0x09 GPL,SL R/W 1 Selective self-test log 0x10 GPL,SL R/O 1 SATA NCQ Queued Error log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 2) == 0x01 0x008 4 1455 --- Lifetime Power-On Resets 0x01 0x010 4 350 --- Power-on Hours 0x01 0x018 6 696530565 --- Logical Sectors Written 0x01 0x020 6 99946104 --- Number of Write Commands 0x01 0x028 6 114530703 --- Logical Sectors Read 0x01 0x030 6 61495417 --- Number of Read Commands 0x02 ===== = = === == Free-Fall Statistics (empty) == 0x03 ===== = = === == Rotating Media Statistics (empty) == 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 66 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (empty) == 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 54188 --- Number of Hardware Resets 0x06 0x018 4 8 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 2 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value SATA Phy Event Counters (GP Log 0x11) not supported /dev/sdb === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint M6 Device Model: SAMSUNG HM251JI Serial Number: -- LU WWN Device Id: 5 0f0000 ... Firmware Version: 2SS00_01 User Capacity: 250 059 350 016 bytes [250 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0 SATA Version is: SATA 2.5, 1.5 Gb/s Local Time is: Thu Dec 7 20:27:00 2017 +05 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 20) The self-test routine was aborted by the host. Total time to complete Offline data collection: ( 85) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0 3 Spin_Up_Time POS--- 252 252 025 - 2812 4 Start_Stop_Count -O--CK 094 094 000 - 6464 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 5 7 Seek_Error_Rate -OSR-- 252 252 051 - 0 8 Seek_Time_Performance --S--K 252 252 015 - 0 9 Power_On_Hours -O--CK 091 091 000 - 4989 10 Spin_Retry_Count -O--CK 100 100 051 - 15 12 Power_Cycle_Count -O--CK 098 098 000 - 2805 191 G-Sense_Error_Rate -O--CK 100 100 000 - 215 192 Power-Off_Retract_Count -O--CK 100 100 000 - 1160 194 Temperature_Celsius -O---K 133 073 000 - 35 (Min/Max 13/55) 195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 7 196 Reallocated_Event_Count -O--CK 252 252 000 - 0 197 Current_Pending_Sector -O--C- 252 252 000 - 0 198 Offline_Uncorrectable ----CK 252 252 000 - 0 199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 1 200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 1 201 Soft_Read_Error_Rate -O--CK 252 252 000 - 0 223 Load_Retry_Count -O--CK 099 099 000 - 1187 225 Load_Cycle_Count -O--CK 100 100 000 - 7991 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x08 SL R/O 1 Power Conditions log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80 GPL,SL R/W 16 Host vendor specific log 0x81-0x9f SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) Device Error Count: 2 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2 [1] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 f0 00 00 00 5e 19 a1 e0 00 Error: ICRC, ABRT 240 sectors at LBA = 0x005e19a1 = 6166945 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 f0 00 00 00 5e 19 a1 e0 00 00:01:16.625 READ DMA EXT Error 1 [0] occurred at disk power-on lifetime: 4 hours (0 days + 4 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 f0 00 00 00 5e 19 a1 e0 00 Error: UNC 240 sectors at LBA = 0x005e19a1 = 6166945 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 f0 00 00 00 5e 19 a1 e0 00 00:01:11.562 READ DMA EXT 25 00 00 00 10 00 00 00 5e 19 91 e0 00 00:01:09.062 READ DMA EXT 25 00 00 00 f0 00 00 00 5e 18 a1 e0 00 00:01:09.062 READ DMA EXT 25 00 00 00 50 00 00 00 5e 18 51 e0 00 00:01:09.062 READ DMA EXT 25 00 00 00 10 00 00 00 5f 9a 01 e0 00 00:01:08.937 READ DMA EXT SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Aborted by host 40% 84 - # 2 Extended offline Completed without error 00% 83 - # 3 Extended offline Interrupted (host reset) 80% 81 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Aborted_by_host [40% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 35 Celsius Power Cycle Min/Max Temperature: 23/36 Celsius Lifetime Min/Max Temperature: 15/54 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 15/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (101) Index Estimated Time Temperature Celsius 102 2017-12-07 18:20 35 **************** ... ..( 49 skipped). .. **************** 24 2017-12-07 19:10 35 **************** 25 2017-12-07 19:11 36 ***************** ... ..( 8 skipped). .. ***************** 34 2017-12-07 19:20 36 ***************** 35 2017-12-07 19:21 35 **************** ... ..( 8 skipped). .. **************** 44 2017-12-07 19:30 35 **************** 45 2017-12-07 19:31 34 *************** ... ..( 48 skipped). .. *************** 94 2017-12-07 20:20 34 *************** 95 2017-12-07 20:21 35 **************** ... ..( 5 skipped). .. **************** 101 2017-12-07 20:27 35 **************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x000a 2 17 Device-to-host register FISes sent due to a COMRESET 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x8001 2 0 Vendor specific


Hardware for Linux and BSD

GitHub