Probe #b4e94f35cb of ASUSTek ROG STRIX Z390-E GAM... Desktop Computer

Log: smartctl

/dev/nvme0n1 smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.4.0-96-generic] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: Samsung SSD 970 EVO Plus 1TB Serial Number: -- Firmware Version: 2B2QEXM7 PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 1,000,204,886,016 [1.00 TB] Unallocated NVM Capacity: 0 Controller ID: 4 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB] Namespace 1 Utilization: 121,695,989,760 [121 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Sat Jan 29 21:50:54 2022 CST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 85 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 7.80W - - 0 0 0 0 0 0 1 + 6.00W - - 1 1 1 1 0 0 2 + 3.40W - - 2 2 2 2 0 0 3 - 0.0700W - - 3 3 3 3 210 1200 4 - 0.0100W - - 4 4 4 4 2000 8000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 30 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 6,616,859 [3.38 TB] Data Units Written: 9,029,401 [4.62 TB] Host Read Commands: 94,832,069 Host Write Commands: 110,533,393 Controller Busy Time: 400 Power Cycles: 207 Power On Hours: 1,077 Unsafe Shutdowns: 3 Media and Data Integrity Errors: 0 Error Information Log Entries: 118 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 30 Celsius Temperature Sensor 2: 30 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged /dev/sda smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.4.0-96-generic] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD4005FZBX-00K5WB0 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: 01.01A01 User Capacity: 4,000,787,030,016 bytes [4.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Jan 29 21:50:54 2022 CST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 87) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 454) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance --S--- 132 132 054 - 96 3 Spin_Up_Time POS--- 148 148 024 - 407 (Average 406) 4 Start_Stop_Count -O--C- 100 100 000 - 1797 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate -O-R-- 100 100 067 - 0 8 Seek_Time_Performance --S--- 128 128 020 - 18 9 Power_On_Hours -O--C- 099 099 000 - 9083 10 Spin_Retry_Count -O--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 788 192 Power-Off_Retract_Count -O--CK 099 099 000 - 2064 193 Load_Cycle_Count -O--C- 099 099 000 - 2064 194 Temperature_Celsius -O---- 137 137 000 - 40 (Min/Max 21/54) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL R/O 256 Device Statistics log 0x04 SL R/O 255 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x0c GPL R/O 5501 Pending Defects log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x12 GPL R/O 1 SATA NCQ Non-Data log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x15 GPL R/W 1 Rebuild Assist log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x24 GPL R/O 256 Current Device Internal Status Data log 0x25 GPL R/O 256 Saved Device Internal Status Data log 0x2f GPL - 1 Set Sector Configuration 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 25/43 Celsius Lifetime Min/Max Temperature: 21/54 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/55 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (41) Index Estimated Time Temperature Celsius 42 2022-01-29 19:43 41 ********************** ... ..( 17 skipped). .. ********************** 60 2022-01-29 20:01 41 ********************** 61 2022-01-29 20:02 42 *********************** ... ..( 12 skipped). .. *********************** 74 2022-01-29 20:15 42 *********************** 75 2022-01-29 20:16 43 ************************ ... ..( 26 skipped). .. ************************ 102 2022-01-29 20:43 43 ************************ 103 2022-01-29 20:44 42 *********************** ... ..( 14 skipped). .. *********************** 118 2022-01-29 20:59 42 *********************** 119 2022-01-29 21:00 41 ********************** ... ..( 24 skipped). .. ********************** 16 2022-01-29 21:25 41 ********************** 17 2022-01-29 21:26 40 ********************* ... ..( 22 skipped). .. ********************* 40 2022-01-29 21:49 40 ********************* 41 2022-01-29 21:50 41 ********************** SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 788 --- Lifetime Power-On Resets 0x01 0x010 4 9083 --- Power-on Hours 0x01 0x018 6 25274687360 --- Logical Sectors Written 0x01 0x020 6 134876768 --- Number of Write Commands 0x01 0x028 6 45159490629 --- Logical Sectors Read 0x01 0x030 6 238324955 --- Number of Read Commands 0x01 0x038 6 32701697500 --- Date and Time TimeStamp 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 8327 --- Spindle Motor Power-on Hours 0x03 0x010 4 8327 --- Head Flying Hours 0x03 0x018 4 2064 --- Head Load Events 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors 0x03 0x028 4 0 --- Read Recovery Attempts 0x03 0x030 4 0 --- Number of Mechanical Start Failures 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 40 --- Current Temperature 0x05 0x010 1 41 N-- Average Short Term Temperature 0x05 0x018 1 41 N-- Average Long Term Temperature 0x05 0x020 1 54 --- Highest Temperature 0x05 0x028 1 21 --- Lowest Temperature 0x05 0x030 1 50 N-- Highest Average Short Term Temperature 0x05 0x038 1 25 N-- Lowest Average Short Term Temperature 0x05 0x040 1 46 N-- Highest Average Long Term Temperature 0x05 0x048 1 25 N-- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 55 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 2140 --- Number of Hardware Resets 0x06 0x010 4 82 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0xff ===== = = === == Vendor Specific Statistics (rev 1) == |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) No Defects Logged SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/sdb smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.4.0-96-generic] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 860 EVO 500GB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: RVT04B6Q User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Jan 29 21:50:54 2022 CST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 098 098 000 - 9007 12 Power_Cycle_Count -O--CK 099 099 000 - 768 177 Wear_Leveling_Count PO--C- 099 099 000 - 11 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 076 049 000 - 24 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 235 POR_Recovery_Count -O--C- 099 099 000 - 12 241 Total_LBAs_Written -O--CK 099 099 000 - 8248563997 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 256 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 24 Celsius Power Cycle Min/Max Temperature: 24/40 Celsius Lifetime Min/Max Temperature: 21/51 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 SMART Status: 0xc24f (PASSED) SCT Temperature History Version: 2 Temperature Sampling Period: 10 minutes Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (22) Index Estimated Time Temperature Celsius 23 2022-01-29 00:40 23 **** 24 2022-01-29 00:50 22 *** ... ..( 2 skipped). .. *** 27 2022-01-29 01:20 22 *** 28 2022-01-29 01:30 ? - 29 2022-01-29 01:40 26 ******* 30 2022-01-29 01:50 31 ************ 31 2022-01-29 02:00 27 ******** 32 2022-01-29 02:10 29 ********** 33 2022-01-29 02:20 30 *********** 34 2022-01-29 02:30 29 ********** 35 2022-01-29 02:40 28 ********* 36 2022-01-29 02:50 28 ********* 37 2022-01-29 03:00 27 ******** 38 2022-01-29 03:10 28 ********* ... ..( 14 skipped). .. ********* 53 2022-01-29 05:40 28 ********* 54 2022-01-29 05:50 29 ********** 55 2022-01-29 06:00 29 ********** 56 2022-01-29 06:10 28 ********* 57 2022-01-29 06:20 28 ********* 58 2022-01-29 06:30 28 ********* 59 2022-01-29 06:40 27 ******** ... ..( 2 skipped). .. ******** 62 2022-01-29 07:10 27 ******** 63 2022-01-29 07:20 26 ******* ... ..( 8 skipped). .. ******* 72 2022-01-29 08:50 26 ******* 73 2022-01-29 09:00 25 ****** ... ..( 11 skipped). .. ****** 85 2022-01-29 11:00 25 ****** 86 2022-01-29 11:10 ? - 87 2022-01-29 11:20 28 ********* 88 2022-01-29 11:30 29 ********** 89 2022-01-29 11:40 26 ******* 90 2022-01-29 11:50 26 ******* 91 2022-01-29 12:00 28 ********* 92 2022-01-29 12:10 27 ******** 93 2022-01-29 12:20 27 ******** 94 2022-01-29 12:30 26 ******* ... ..( 2 skipped). .. ******* 97 2022-01-29 13:00 26 ******* 98 2022-01-29 13:10 27 ******** ... ..( 5 skipped). .. ******** 104 2022-01-29 14:10 27 ******** 105 2022-01-29 14:20 28 ********* 106 2022-01-29 14:30 27 ******** 107 2022-01-29 14:40 28 ********* 108 2022-01-29 14:50 27 ******** 109 2022-01-29 15:00 27 ******** 110 2022-01-29 15:10 26 ******* 111 2022-01-29 15:20 27 ******** 112 2022-01-29 15:30 26 ******* 113 2022-01-29 15:40 25 ****** ... ..( 2 skipped). .. ****** 116 2022-01-29 16:10 25 ****** 117 2022-01-29 16:20 24 ***** 118 2022-01-29 16:30 ? - 119 2022-01-29 16:40 26 ******* ... ..( 7 skipped). .. ******* 127 2022-01-29 18:00 26 ******* 0 2022-01-29 18:10 25 ****** 1 2022-01-29 18:20 25 ****** 2 2022-01-29 18:30 25 ****** 3 2022-01-29 18:40 26 ******* ... ..( 7 skipped). .. ******* 11 2022-01-29 20:00 26 ******* 12 2022-01-29 20:10 28 ********* 13 2022-01-29 20:20 28 ********* 14 2022-01-29 20:30 26 ******* 15 2022-01-29 20:40 26 ******* 16 2022-01-29 20:50 25 ****** 17 2022-01-29 21:00 25 ****** 18 2022-01-29 21:10 25 ****** 19 2022-01-29 21:20 24 ***** ... ..( 2 skipped). .. ***** 22 2022-01-29 21:50 24 ***** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 768 --- Lifetime Power-On Resets 0x01 0x010 4 9007 --- Power-on Hours 0x01 0x018 6 8248563997 --- Logical Sectors Written 0x01 0x020 6 38357374 --- Number of Write Commands 0x01 0x028 6 9410181777 --- Logical Sectors Read 0x01 0x030 6 51964995 --- Number of Read Commands 0x01 0x038 6 1715000 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 24 --- Current Temperature 0x05 0x020 1 51 --- Highest Temperature 0x05 0x028 1 21 --- Lowest Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 3797 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC


Hardware for Linux and BSD

GitHub